14. Unique cement fibre wall board installation cut above floor level:
Cutting Villaboard above floor level to avoid capillary action. Silicone placed both sides on lowest edge of Villaboard with gloves, Avoids discolouration of tiles due to water absorption in the tile biscuit. Water stain can rise in wallboard and tile to a height of one metre, affecting adhesion of adhesive, and can cause tile failure.